ATS1210LE
8 to 16 zone DGP input expander, large plastic housing, EN50131 Grade 3 Class II
- 8 inputs on board
- Expandable to 16 inputs
- 8 OC outputs on board
- Compatible with Axon and Advisor Advanced panels
- ATS1647 plastic enclosure with tamper protection
At a glance
Product overview
The ATS1210LE expander offers 8 standard inputs and 8 Open Collector (OC) outputs expandable to 16 inputs or 16 outputs and is provided in the ATS1647 medium plastic housing. The expanders allow to increase the inputs and outputs of an Axon or an Advisor Advanced control panel or CDC4 series door/lift controller.
Expanders
Expanders are used to expand the number of alarm inputs in an Axon panel or an Advisor Advanced system. Expanders allow inputs and outputs/relays to be connected at a location remote from an Axon or an Advisor Advanced panel. Expanders communicate via poll & reply messages. Detectors, door contacts and other detection devices are connected to expanders that report any change of state to the control panel for processing. Available expanders include support for conventional devices, wireless devices as well as intelligent addressable devices. A special expander is available, providing expansion of four to eight intelligent doors or lifts.
System databus connection
The system databus is used to connect expanders as well as keypads and readers (RASs) to Axon or the Advisor Advanced control panel. Remote devices can be up to 1.5 km from a control panels when using the preferred wiring and cable types. Keypads, readers and expanders have to be connected via a 2 pair twisted and shielded data cable to the system databus connection to achieve this. (WCAT52 is recommended). Daisy chain is the preferred wiring method. The shield of the data cable should be connected to earth at the control panel and should be left disconnected at any other end.
Functionality
Expanders provide information from remote locations to the control panels in structured records. Data collected ranges from a wired input state to wireless or addressable device dates to a door state.
Bus devices communicate with the control panel. If a failure in communication occurs, the expander remembers the last alarm in a system, preventing loss of an alarm due to a short interruption in data communication.
Up to 30 expanders can be connected to the system, depending on the variant.
Bus devices communicate with the control panel. If a failure in communication occurs, the expander remembers the last alarm in a system, preventing loss of an alarm due to a short interruption in data communication.
Up to 30 expanders can be connected to the system, depending on the variant.
Details
- 8 inputs on board
- Expandable to 16 inputs
- 8 OC outputs on board
- Compatible with Axon and Advisor Advanced panels
- ATS1647 plastic enclosure with tamper protection
- EN50131 Grade 3
- PD6662:2010
Technical specifications
| General | ||
|---|---|---|
| Expander type |
Input expander
|
|
| Product line |
Advisor Advanced
ATS Master
Axon
|
|
| Connection type |
Databus connection
|
|
| Compatibility |
Advisor Advanced, Advisor Master and Axon
|
|
| Max. distance from panel |
1.5 km
|
|
| Max. per panel |
15 / 30 (depending on panel type)
|
|
| Specified cable |
WCAT52 / WCAT54 or equivalent
|
|
| System | ||
|---|---|---|
| Addressing |
DIP Switches
|
|
| End-of-line resistor |
Selectable
|
|
| Inputs | ||
|---|---|---|
| Total |
16
|
|
| Onboard |
8
|
|
| Expandable |
8 (1x ATS1202)
|
|
| Outputs | ||
|---|---|---|
| Total |
16
|
|
| Onboard |
8
|
|
| Expandable |
8
|
|
| Type of outputs |
Open Collector
|
|
| Relays |
Via ATS1810 / ATS1811
|
|
| Maximum number of outputs |
16
|
|
| Electrical | ||
|---|---|---|
| Operating voltage |
10.5 to 13.8 VDC
|
|
| Current consumption |
53 mA max.
|
|
| Integrated power supply |
No
|
|
| Physical | ||
|---|---|---|
| Physical dimensions |
120 x 240 x 40 mm
|
|
| Net weight |
390 gr
|
|
| Material |
ABS
|
|
| Housing |
Medium Plastic
|
|
| Environmental | ||
|---|---|---|
| Operating temperature |
-10 to +55°C
|
|
| Relative humidity |
95% noncondensing
|
|
| Environment |
EN50130-5 ; Class II - Indoor (general)
|
|
| IP rating |
IP30
|
|
| Regulatory | ||
|---|---|---|
| Compliancy |
CE
|
|
| Certification |
EN50131 Grade 3
VdS
|
|
Downloads
All downloadsDatasheet
Other EU certificate
Other EU certificate
G106047
Other EU certificate
6281-10-4_20240418
Other EU certificate
1221100036A16
Other EU certificate
1231100032B15
Other EU certificate
1223000003A17
Other EU certificate
1231100043A15
Other EU certificate
1233000005A17
Other EU certificate
1221100045C0
Other EU certificate
1231100045A0
Other EU certificate
1231100045C0
Other EU certificate
1231100045B0
Other EU certificate
1221100045C1
Other EU certificate
1231100045A1
Other EU certificate
1231100045B1
Other EU certificate
1231100045C1
Other EU certificate
1231100045D0
Other EU certificate
1223000009A1
Other EU certificate
1233000006A1
Other EU certificate
1233000007A1
Other EU certificate
13229070/AA/05
Other EU certificate
1233000008A1
Installation sheet
Technical documentation
Certificates