Programmable Inputs
The Input/Output functional module extends the MiniLaser’s interface capabilities by providing programmable ASD inputs that support key external control and supervision functions. These inputs can be configured for Remote Day/Night Mode changeover, Remote Reset, and ClassiFire Override, in addition to power-supply fault monitoring, enabling seamless integration with fire alarm control panels, building management systems, and site-specific control logic.
ClassiFire Override is a particularly valuable function, allowing the detector’s normal sensitivity to be temporarily reduced by a pre-programmed percentage. This feature is designed to accommodate predictable and controlled environmental conditions that may otherwise lead to unwanted alarms, such as theatre stage effects, controlled smoke release, or open fires in heritage buildings. By dynamically adjusting sensitivity while maintaining full aspirating detection functionality, ClassiFire Override supports operational continuity without compromising overall system integrity.
ClassiFire Override is a particularly valuable function, allowing the detector’s normal sensitivity to be temporarily reduced by a pre-programmed percentage. This feature is designed to accommodate predictable and controlled environmental conditions that may otherwise lead to unwanted alarms, such as theatre stage effects, controlled smoke release, or open fires in heritage buildings. By dynamically adjusting sensitivity while maintaining full aspirating detection functionality, ClassiFire Override supports operational continuity without compromising overall system integrity.
Programmable Outputs
The Input/Output functional module extends the MiniLaser’s interface capability by providing additional programmable outputs for enhanced external signalling and system integration. The Input/Output functional module adds five additional programmable outputs, complementing the detector’s standard relay outputs and increasing flexibility for connection to fire alarm control panels, building management systems, and other external monitoring or control interfaces. The five outputs may be used to report the 4 alarm levels of the ASD, plus an additional fault output. Being able to report all 4 alarm levels is a requirement in certain applications where various actions or alarms are required based on the development of smoke and/or fire.
Configuration
All input and output functions can be configured using the Remote configuration software via the MiniLaser USB-C interface, allowing full access to advanced settings, diagnostics, and maintenance features. For rapid installation and commissioning, MiniLaser also supports an easy dip-switch configuration mode, enabling operation without a PC. When this installation mode is used, the inputs and outputs operate with preloaded default behaviors, ensuring predictable and standardized functionality straight out of the box while still allowing later refinement through software if required.
Specifiche tecniche
| Environmental | ||
|---|---|---|
| Environment |
Indendør
|
|
| Regulatory | ||
|---|---|---|
| Certification |
CPR
EN54-20
|
|
Scaricamenti
All downloadsDatasheet
Foglio di installazione
Certificati
DoP
KGS F&S - DoP_3103107-ML_9-30501
DoP
KGS F&S - DoP_3103108-ML_FHSD8075
DoP
KGS F&S - DoP_3103109-ML_9-30501-KID
DoC
KGS F&S - DoC_3103112-ML_9-30501
DoC
KGS F&S - DoC_3103113-ML_FHSD8075
DoC
KGS F&S - DoC_3103114-ML_9-30501-KID
DoC
KGS F&S - DoC_3103115-ML_9-30501-AUT
DoC
KGS F&S - DoC_3103116-ML_9-30501-HOC
DoP
KGS F&S - DoP_3103110-ML_9-30501-AUT
DoP
KGS F&S - DoP_3103111-ML_9-30501-HOC
Certificato extra UE
ULUS - VMC_UL-US-26114165-0_9-30520
Certificato extra UE
CSFM - VMC_7259-2342:0506_MiniLaser UL
Se disponibili, i download di Certificati, Software e Firmware e Supporti vengono visualizzati nella lingua predefinita.